CTS GUIDE · CUMMINS INSITE

Before programming a Cummins, back up the ECM.

In INSITE, create a template with the configuration the ECM has right now. If you later need to see how it was or bring a parameter back, you already have the reference.

6 stepsin INSITE
5 minutesbefore programming
3 backupstemplate, image and dataplate
CTS technician checking an ECM's configuration on a laptop at the Houston lab
CTSThis is how we do it at the Houston lab before every programming job.
Programming without saving the original information first is working without a backup. The more information you have before you start, the better.

Before touching anything

What you need to save

Three backups of every ECM. Without them, if something goes wrong, there is no way back to how it came.

Cummins CM2350 ECM with its two connectors
01

The template

Features and Parameters as they come: max road speed, cruise, idle shutdown, PTO and the rest.

INSITE · Template
02

The ECM image

A full snapshot of the ECM: parameters, calibration and trip data. It opens without being connected.

INSITE · ECM Image
03

The engine data

ESN, CPL, calibration code and revision. A photo of the engine dataplate and of the ECM label.

Engine dataplate · ECM label

Step by step

How to make the backup in INSITE

Key ON, engine off. Menu names may change a little depending on your INSITE version.

  1. Connect to the ECM

    Your interface (INLINE or another RP1210) on the diagnostic connector. Open INSITE and connect.

  2. Write down the identification

    ESN, CPL, calibration and revision, in the ECM summary. Compare them with the engine dataplate.

  3. Create the template

    Open Features and Parameters and save them as a template. Put the unit or the ESN and the date in the name.

  4. Create the ECM image

    From the same connection, save the ECM image.

  5. Copy it off the laptop

    To a USB drive or the cloud. If the laptop fails, the backup goes with it.

  6. Now you can program

    If you need to bring a parameter back, open the template and compare.

So they don't get mixed up

Template or image: save both

ItemTemplateECM image
What it savesThe Features and ParametersParameters, calibration and trip data
What it's forComparing and bringing parameters back after programmingSeeing how the whole ECM was, without connecting
WhenAlways, before changing any parameterAlways, before loading a calibration

Before changing a calibration

A rating gets changed only to another Cummins-certified rating for that engine and that CPL. Our 27-point checklist before raising HP and torque is the step that comes first.

Cummins programming

Would you rather we do it?

CTS programs Cummins ECMs in Houston and remotely, with a backup before touching anything. Send us a photo of the engine dataplate and we'll tell you what can be done.

See how we program your ECM →

For the shop

Work Cummins ECMs on the bench

Read, back up and program out of the truck. You buy the base cable once and it works with every adapter.

The video

The video that brought you here

@cartuningstarcts

Going to program a Cummins? Learn what to check before connecting the ECM.

Watch on TikTok

← All the shop-floor guides